Length Measuring Machine

Send Inquiry
Length Measuring Machine
Details
Absolute measurement range: 350 mm
Grating scale length: 350 mm
Highest resolution: 0.001µm
Maximum allowable error:[0.085 + L(mm)/2000]µm
Measuring force: 0-12N, continuously adjustable
Electronic sensor measuring force: 0.3N
Universal workbench can be easily moved along the X-axis direction
Heidenhain high-precision new grating measurement system
Built-in temperature compensation system for real-time compensation
Category
Precision Measurement Instrument
Share to
Description
 

Product Introduction

 

The NANO-CHECK Length Measuring Machine series stands as a pinnacle of high-precision length measurement, engineered to meet the rigorous demands of modern metrology laboratories. At its core lies a custom-developed grating measurement system co-created with Heidenhain, a globally renowned German brand synonymous with precision engineering. This collaboration ensures that every NANO-CHECK Length Measuring Machine unit delivers not just accuracy, but consistent reliability-critical for length dimension traceability, where even the smallest deviation can compromise quality control.

 

One of the most compelling advantages of the NANO-CHECK Length Measuring Machine is its dual measurement capability: absolute and relative. With an absolute measurement range of 350 mm (and relative ranges extending up to 1100 mm across models), it covers a wide spectrum of measurement tasks, from calibrating tiny gauge blocks to larger components like rulers or calibration rods. The 350 mm grating scale length is a key differentiator, as it eliminates the need for incremental position resetting, enabling seamless, continuous measurement while maintaining high precision.

 

Precision is further elevated by the machine's exceptional resolution of 0.001 μm-a level of detail that ensures even micro-scale dimensional variations are detected. Complementing this is its ultra-low maximum allowable error of [0.085 + L(mm)/2000] μm, where "L" represents the measured length. For example, when measuring a 200 mm component, the maximum allowable error is just 0.185 μm-far below industry standards for similar equipment. This makes the NANO-CHECK Length Measuring Machine an ideal choice for labs requiring traceable, ISO-compliant measurements.

 

The machine's robustness is another standout feature. Its base is crafted from specialty cast materials, selected for their superior stability, vibration resistance, and thermal inertia. This design minimizes external interference (such as ambient vibrations or temperature fluctuations) that could affect measurement accuracy, ensuring consistent performance even in high-traffic lab environments. Whether used for daily calibration tasks or critical research applications, the delivers the precision and durability that metrologists trust.

 

Dimensions & Spec.

 

product-1268-381

 

 

Technical Parameters

 

Model

 

NANO-CHECK 350

NANO-CHECK 600

NANO-CHECK 1100

Absolute Measurement Range

mm

350 mm

350 mm

350 mm

Relative Measurement Range

mm

0-350 mm

0-600 mm

0-1100 mm

Maximum Allowable Error

μm

[0.085 + L(mm)/2000] μm

Maximum Resolution

μm

0.001 μm

Repeatability (2S)

μm

0.03 μm

Force measurement (software adjustable)

N

0-12 N

Ambient Temperature

°C

+10 to +40 °C

Relative Humidity

%

20-80%

Weight

Kg

350

420

500

Calibration requirements

 

Humidity 50% ±5%;calibration temperature 20°C ±0.2°C; temperature gradient ≤0.5°C / hour

It can be used with different accessories

 

 

Applications

 

The NANO-CHECK's precision is not just a specification-it's a promise backed by advanced engineering. Its Heidenhain grating system uses optical technology to capture position data with microscopic accuracy, while the 0.001 μm resolution ensures that even the smallest dimensional changes (e.g., thermal expansion of a gauge block) are detected. The 0.03 μm repeatability (2S) further guarantees that measurements are consistent across multiple trials, eliminating variability and ensuring traceability to international standards (such as ISO 10360).

This level of precision makes the NANO-CHECK indispensable for calibrating a wide range of measuring instruments, including:

Gauge blocks

The "building blocks" of metrology, requiring ultra-high precision calibration.

01

Ring gauges

Smooth, threaded, and tapered variants, used to verify the outer dimensions of components.

02

Bearing components

Inner and outer raceways, where dimensional accuracy directly impacts bearing performance and lifespan.

03

Handheld tools

Calipers, rulers, and calibration rods, ensuring field measurements remain accurate.

04

Spline gauges

Critical for automotive and aerospace applications, where spline fit affects mechanical performance.

05

 

 

FAQ

 

Q1: What makes the NANO-CHECK's grating system superior to other measurement technologies?

A: The NANO-CHECK uses a custom Heidenhain grating system-a key advantage over generic systems. Heidenhain's grating technology is renowned for its stability (resistant to wear and environmental interference) and accuracy (delivering consistent results even after years of use). Unlike laser-based systems, which can be affected by dust, air turbulence, or surface reflections, the grating system relies on physical scale markings, ensuring reliable measurements in real-world lab conditions.

Q2: Can the NANO-CHECK measure both small and large components?

A: Yes. The machine's dual measurement ranges make it versatile for both small and large components. The absolute measurement range (350 mm) is ideal for smaller items like gauge blocks or caliper jaws, while the relative range (extending up to 1100 mm for the NANO-CHECK 1100) handles larger components such as rulers, calibration rods, or even small machine parts. This eliminates the need for multiple machines, saving lab space and cost.

Q3: How does the temperature compensation system work, and is it necessary?

A: The built-in temperature compensation system uses high-precision sensors to monitor the temperature of the machine's base, the grating scale, and the measured component. It then applies mathematical corrections based on the thermal expansion coefficients of the materials involved (e.g., steel, aluminum). This is critical because even small temperature changes (e.g., ±1 °C) can cause dimensional shifts of several micrometers-enough to invalidate high-precision measurements. Without compensation, labs would need strict climate control (costly to maintain) to ensure accuracy; with it, the NANO-CHECK maintains precision in more flexible environments.

Q4: What accessories are available for the NANO-CHECK, and how do they enhance its functionality?

A: A wide range of accessories is available to tailor the NANO-CHECK to specific tasks, including:
•Specialized fixtures: For holding non-standard components (e.g., tapered ring gauges or spline gauges) securely during measurement.
•Electronic force sensors: For applications requiring precise control of measuring force (e.g., measuring delicate components that could deform under high force).
•Data management software: To automate measurement logging, generate calibration reports, and integrate with lab information management systems (LIMS).
•Calibration standards kits: To verify the machine's performance regularly, ensuring compliance with ISO or national metrology standards.
These accessories transform the NANO-CHECK from a standard measuring machine into a fully customized solution for your lab's unique needs.

Q5: What is the expected lifespan of the NANO-CHECK, and how often does it need calibration?

A: With proper maintenance (regular cleaning, lubrication of moving parts, and adherence to calibration schedules), the NANO-CHECK has an expected lifespan of 10–15 years-a testament to its robust construction and high-quality components. For calibration, we recommend:
•Annual calibration by an accredited metrology service to ensure compliance with international standards.
•Interim checks (every 3–6 months) using certified calibration standards (e.g., gauge blocks) to verify performance between formal calibrations.
•Immediate recalibration if the machine is moved, Experience a major environmental change (e.g., a temperature spike), or if measurement results show unexpected variability.

Hot Tags: length measuring machine, China length measuring machine manufacturers, suppliers, factory, Two dimensional Height Gauge, Ball Diameter Measuring Instrument, Thread Comprehensive Measuring Machine, Measuring System for Quick Determination Of Hydrogen, Straightness Gauge, Indicator Gauge Calibrator

Send Inquiry