Flashback Arrestors for reliable protection against dangerous reverse gas flow and flashbacks according to DIN EN ISO 5175-1.
Every Arrestor 100% tested.
The best Flashback Arrestors in the world
● A large surface area flame arrestor FA of stainless steel construction extinguishes any dangerous flashback
● A temperature sensitive cut-off valve TV extinguishes sustained flashbacks long before the internal temperature of the arrestors reaches a dangerous level
● A spring loaded non-return valve NV prevents slow or sudden reverse gas flow from forming explosive mixtures in the gas supply
● A filter at the gas inlet protects the arrestor against dirt contamination, extending the service life (only 85-10)
Operation / Usage
● Flashback Arrestors are used to protect gas cylinders and pipeline outlet points (hoses and any equipment) against dangerous reverse gas flow and flashbacks
● For pipeline outlets and single cylinders with high users for example supply units for gas cutting machines: Model 85-10
● For torches or burners with high flow: Models 85- 10NU and 85-10 eccentric = eccentric outlet
● For cutting machines with high flow: Model 85-10U
● Flashback Arrestors may be mounted in any position /orientation
● Only one piece of equipment may be connected to a single Flashback Arrestor
● The maximum ambient / working temperature is 60 °C / 140 °F
Maintenance
● Annual testing of the non-return valve, body leak tightness and flow capacity is recommended
● We are happy to supply special test equipment
● Flashback Arrestors are only to be serviced by the manufacturer; the dirt filter may be replaced according to model by competent staff
Approvals
Company certified according to ISO 9001 and PED 2014/68/EU Module H CE-marked according to: - PED 2014/68/EU
Designed for Oxygen Service in accordance with EIGA 13/20 and CGA G-4.4: Oxygen Pipeline and Piping Systems
Cleaned for Oxygen Service in accordance with EIGA 33/18 and CGA G-4.1: Cleaning of Equipment for Oxygen Service
|
Safety devices |
Model |
|||||
|
85-10 |
85-10NU |
85-10U |
85-10 eccentric |
|||
|
Flame arrestor FA |
|
|
|
|
||
|
Non-return valve NV |
|
|
|
|
||
|
Temperature sensitive cut-off valve TV |
|
|
– |
|
||
|
Weight [g] |
434 |
434 |
434 |
417 |
||
|
Certification IBExU |
IBExU 2405 |
– |
– |
– |
||
|
Material |
Housing - Brass; Flame arrestor - Stainless steel; Seal - Elastomer |
|||||
|
Model |
||||
|
85-10 |
85-10NU |
85-10U |
85-10 eccentric |
|
|
Gases |
max. working pressure [bar] |
|||
|
Acetylene (A) |
1.5 |
1.5 |
- |
1.5 |
|
Town gas (C)* |
5.0 |
5.0 |
5.0 |
5.0 |
|
Natural gas (M) |
5.0 |
5.0 |
5.0 |
5.0 |
|
LPG (P) |
5.0 |
5.0 |
5.0 |
5.0 |
|
Hydrogen (H) |
4.0 |
4.0 |
4.0 |
4.0 |
|
Ethylene (E)* |
5.0 |
5.0 |
5.0 |
5.0 |
|
Connections |
Order-No. |
|||
|
G 3/8 LH |
143-002 |
143-039 |
143-223 |
143-217 |
|
G 1/2 LH |
143-008 |
143-231 |
143-040 |
- |
|
9/16" - 18 UNF LH |
143-009 |
- |
143-245 |
143-131 |
|
Model |
||||
|
85-10 |
85-10NU |
85-10U |
85-10 eccentric |
|
|
Gases |
max. working pressure [bar] |
|||
|
Oxygen (O) |
25.0 |
25.0 |
25.0 |
25.0 |
|
Compressed air (D) |
25.0 |
25.0 |
25.0 |
25.0 |
|
Connections |
Order-No. |
|||
|
G 1/4 RH |
143-013 |
- |
- |
143-215 |
|
G 3/8 RH |
143-016 |
143-041 |
143-133 |
143-216 |
|
G 1/2 RH |
143-019 |
- |
143-042 |
143-152 |
|
9/16" - 18 UNF RH |
143-022 |
- |
143-244 |
143-132 |
* no Certification IBExU

Hot Tags: flashback arrestors 85-10, China flashback arrestors 85-10 manufacturers, suppliers, factory, RF Flashback Arrestors, Flashback Arrestors 85 10, flashback arrestors, Flashback Arrestors 85 20